 Rev 2; 9/08
I2C Digital Input RTC with Alarm
General Description
The DS1375 digital real-time clock (RTC) is a low-power clock/calendar that does not require a crystal. The device operates from a digital clock input pin at one of four frequencies: 32.768kHz, 8.192kHz, 60Hz, or 50Hz. It maintains seconds, minutes, hours, day, date, month, and year information. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including corrections for leap year. The clock operates in either the 24-hour or 12-hour format with an AM/PM indicator. Two programmable time-of-day/date alarms, a programmable square-wave output, and 16 bytes of SRAM are provided. Address and data are transferred serially through an I2C bidirectional bus.
Features
RTC Counts Seconds, Minutes, Hours, Day, Date, Month, and Year with Leap-Year Compensation Valid Up to 2100 Two Programmable Alarms Programmable Square-Wave Output Operates from a 32.768kHz, 8.192kHz, 60Hz, or 50Hz Digital Clock Signal 16 Bytes of SRAM Fast (400kHz) I2C Interface 1.7V to 5.5V Operation
DS1375
Applications
RTC Complement to the DS32kHz TCXO Utility Meters Appliances Consumer Electronics Automotive
PART DS1375T+
Ordering Information
TEMP RANGE -40C to +85C PIN-PACKAGE TOP MARK 6 TDFN-EP* DS1375
+Denotes a lead-free/RoHS-compliant package. *EP = Exposed pad.
Typical Operating Circuit
TOP VIEW
+3V RPU = tr/CB
Pin Configuration
RPU
RPU
+
CLK
VCC SCL SCA CLK VBAT VCC
1
6
VCC SCL
SQW/INT
2
DS1375
*EP
5
CPU
DS1375
INT SQWINT
DS32kHz
GND
3
4
SDA
GND
GND
TDFN (3mm x 3mm)
*EXPOSED PAD
______________________________________________ Maxim Integrated Products
1
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim's website at www.maxim-ic.com.
I2C Digital Input RTC with Alarm DS1375
ABSOLUTE MAXIMUM RATINGS
Voltage Range on VCC Pin Relative to Ground.............................................-0.3V to +6.0V Voltage Range on SDA, SCL, and WDS Relative to Ground ....................................-0.3V to VCC + 0.3V Operating Temperature Range ...........................-40C to +85C Storage Temperature Range .............................-55C to +125C Soldering Temperature...........................Refer to the IPC/JEDEC J-STD-020 Specification.
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED DC OPERATING CONDITIONS
(VCC = +1.7V to +5.5V, TA = -40C to +85C, unless otherwise noted. Typical values are at VCC = 3.3V, TA = +25C, unless otherwise noted.) (Note 1)
PARAMETER Supply Voltage Timekeeping Voltage Input Logic 1 (SDA, SCL) Supply Voltage, Pullup (SQW/INT, CLK) Input Logic 0 Input Leakage (SCL, CLK) I/O Leakage (SDA, SQW/INT) SDA Logic 0 Output SYMBOL VCC VTK VIH VPULLUP VIL ILI ILO IOLSDA VCC > 2V; VOL = 0.4V VCC < 2V; VOL = 0.2 x VCC VCC > 2V; VOL = 0.4V SQW/INT Logic 0 Output Active Supply Current Standby Current IOLSQW ICCA ICCS 1.7V < VCC < 2V; VOL = 0.2 x VCC 1.3V < VCC < 1.7V; VOL = 0.2 x VCC (Notes 5, 6) (Notes 6, 7) 33 150 (Note 2) (Note 2) (Note 2) (Notes 2, 3) (Notes 2, 4) -0.3 -1 -1 CONDITIONS MIN 1.7 1.3 0.7 x VCC TYP 3.3 MAX 5.5 5.5 VCC + 0.3 5.5 +0.3 VCC +1 +1 3.0 3.0 250 150 500 UNITS V V V V V A A mA mA A A nA
Note 1: Note 2: Note 3:
Note 4: Note 5: Note 6: Note 7:
Limits at -40C are guaranteed by design and not production tested. All voltages are referenced to ground. For the CLK pin, input voltages above VCC + 0.3V cause current to flow into the device. The input current must not exceed the current drawn by the circuit that is connected to VCC. Otherwise, current flows out of the DS1375, raising the voltage level on the VCC bus. VIL MIN on the CLK pin can exceed -0.3V as long as the current is limited to less than 1mA. ICCA--SCL clocking at max frequency = 400kHz. CLK pin running at 32,768Hz, rise and fall times at 10ns or less. Specified with I2C bus inactive.
2
_____________________________________________________________________
I2C Digital Input RTC with Alarm
AC ELECTRICAL CHARACTERISTICS
(VCC = VCCMIN to VCCMAX, TA = -40C to +85C, unless otherwise noted.) (Note 1, Figure 1)
PARAMETER SCL Clock Frequency Bus Free Time Between STOP and START Conditions Hold Time (Repeated) START Condition (Note 8) Low Period of SCL Clock High Period of SCL Clock Data Hold Time (Notes 9, 10) Data Setup Time (Note 11) Start Setup Time Rise Time of Both SDA and SCL Signals (Note 12) Fall Time of Both SDA and SCL Signals (Note 12) Setup Time for STOP Condition Capacitive Load for Each Bus Line (Note 12) Pulse Width of Spikes that Must be Suppressed by the Input Filter SYMBOL fSCL tBUF tHD:STA tLOW tHIGH tHD:DAT tSU:DAT tSU:STA tR tF tSU:STO CB tSP Fast mode 30 Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode Fast mode Standard mode CONDITIONS MIN 100 0 1.3 4.7 0.6 4.0 1.3 4.7 0.6 4.0 0 0 100 250 0.6 4.7 20 + 0.1CB 20 + 0.1CB 0.6 4.7 400 300 1000 300 300 0.9 0.9 TYP MAX 400 100 UNITS kHz s s s s s ns s ns ns s pF ns
DS1375
Note 8: Note 9: Note 10: Note 11:
Note 12:
After this period, the first clock pulse is generated. A device must internally provide a hold time of at least 300ns for the SDA signal (see the VIHMIN of the SCL signal) to bridge the undefined region of the falling edge of SCL. The maximum tHD:DAT is only met if the device does not stretch the low period (tLOW) of the SCL signal. A fast-mode device can be used in a standard-mode system, but the requirement tSU:DAT 250ns must then be met. This is automatically the case if the device does not stretch the low period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line tR MAX + tSU:DAT = 1000 + 250 = 1250ns before the SCL line is released. CB--total capacitance of one bus line in pF.
_____________________________________________________________________
3
I2C Digital Input RTC with Alarm DS1375
SDA
tBUF tLOW tR tF
tHD:STA
tSP
SCL tHD:STA STOP START tHD:DAT tHIGH tSU:DAT REPEATED START tSU:STA tSU:STO
Figure 1. Data Transfer on I2C Serial Bus
8192Hz/4096Hz/1024Hz/1Hz CLK DIVIDER 1Hz
MUX/ BUFFER
SQW/INT
CONTROL LOGIC
ALARM AND CONTROL REGISTERS
DS1375
CLOCK AND CALENDAR REGISTERS SRAM
SCL
SDA
SERIAL BUS INTERFACE AND ADDRESS REGISTER
USER BUFFER (7 BYTES)
Figure 2. Functional Diagram
4
_____________________________________________________________________
I2C Digital Input RTC with Alarm
Typical Operating Characteristics
(VCC = +3.3V, TA = +25C, unless otherwise noted.)
DS1375
ICCS vs. VCC
DS1375 toc01
ICCA vs. VCC
90 80 SUPPLY CURRENT (A) 70 60 50 40 30 20 10
DS1375 toc02
300
100
250 SUPPlY CURRENT (nA)
200
150
100
50 1.7 2.2 2.7 3.2 3.7 4.2 4.7 5.2 VCC (V)
0 1.7 2.2 2.7 3.2 3.7 4.2 4.7 5.2 VCC (V)
ICCS vs. TEMPERATURE
DS1375 toc03
ICCS vs. CLK INPUT VOLTAGE
450 400 SUPPLY CURRENT (A) 350 300 250 200 150 100 50 0 VCC = 4.0V VCC = 5.0V
DS1375 toc04
135.0 132.5 VCC = 3.0V SUPPLY CURRENT (nA) 130.0 127.5 125.0 122.5 120.0 117.5 115.0 -40 -20 0 20 40 60 80 TEMPERATURE (C)
500
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 CLK VOLTAGE (V)
_____________________________________________________________________
5
I2C Digital Input RTC with Alarm DS1375
Pin Description
PIN 1 2 3 4 NAME CLK SQW/INT GND SDA FUNCTION Digital Clock Input. This pin must be 32,768Hz, 8192Hz, 60Hz, or 50Hz square wave, 45% to 55% duty cycle. Square-Wave/Interrupt Output. This pin is open drain and requires an external pullup resistor. The pullup voltage can be up to 5.5V, regardless of the voltage on VCC. Ground Serial Data Input/Output. SDA is the data input/output for the I2C serial interface. It is open drain and requires an external pullup resistor. The pullup voltage can be up to 5.5V, regardless of the voltage on VCC. Serial Clock Input. SCL is the clock input for the I2C serial interface, and is used to synchronize data movement on the serial interface. Up to 5.5V can be used for this pin, regardless of the voltage on VCC. DC Power for Primary Power Supply Exposed Pad. Can be connected to ground.
5 6 --
SCL VCC EP
Detailed Description
The DS1375 digital input RTC with alarm is a low-power clock/calendar with two programmable time-of-day alarms and a programmable square-wave output. Address and data are transferred serially through the I2C serial interface bus. The clock/calendar provides seconds, minutes, hours, day, date, month, and year information. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including corrections for leap year. The clock operates in either the 24-hour or 12-hour format with an AM/PM indicator. The DS1375 requires an external clock source selectable between 32,768Hz, 8192Hz, 60Hz, or 50Hz for the timekeeping function. Sixteen bytes of SRAM are provided for additional user storage. When power is applied, the time and date registers are reset to 01/01/00 01 00:00:00 (MM/DD/YY DOW HH:MM:SS).
Address Map
Table 1 shows the address map for the timekeeping registers and SRAM. The 16 bytes of SRAM occupy addresses 10h-1Fh. During a multibyte access, when the address pointer reaches the end of the register space (1Fh), it wraps around to location 00h. On a I2C START, STOP, or address pointer incrementing to location 00h, the current time is transferred to a second set of registers. The time information is read from these secondary registers, while the clock may continue to run. This eliminates the need to reread the registers in case the main registers update during a read. Note: Unless otherwise specified, the state of the registers is not defined when power is first applied.
Clock and Calendar
The time and calendar information is obtained by reading the appropriate register bytes. Table 1 shows the RTC registers. The time and calendar data are set or initialized by writing the appropriate register bytes. The contents of the time and calendar registers are in the binary-coded decimal (BCD) format. The DS1375 can be run in either 12-hour or 24-hour mode. Bit 6 of the hours register is defined as the 12- or 24-hour mode select bit. When high, the 12-hour mode is selected. In the 12-hour mode, bit 5 is the AM/PM bit with logic high being PM. In the 24-hour mode, bit 5 is the second 10hour bit (20-23 hours). The century bit (bit 7 of the
Operation
The DS1375 operates as a slave device on the serial bus. Access is obtained by implementing a START condition and providing a device identification code, followed by data. Subsequent registers can be accessed sequentially until a STOP condition is executed. The functional diagram in Figure 2 shows the main elements of the serial RTC.
6
_____________________________________________________________________
I2C Digital Input RTC with Alarm DS1375
Table 1. Timekeeping Registers and SRAM
ADDRESS 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h-1Fh A1M1 A1M2 A1M3 A1M4 A2M2 A2M3 A2M4 ECLK 0 B7 12/24 DY/DT 12/24 DY/DT BIT 7 0 0 0 0 0 Century 12/24 0 0 0 10 Year 10 Seconds 10 Minutes AM/PM 10 Hours 10 Hours 0 BIT 6 BIT 5 10 Seconds 10 Minutes AM/PM 10 Hours 0 10 Date 10 Month 10 Hours 0 0 Date Months Year Seconds Minutes Hours Day 10 Date 10 Minutes AM/PM 10 Hours -- 10 Date RS2 0 B4 RS1 0 B3 10 Hours Date Minutes Hours Day Date INTCN 0 B2 A2IE A2F B1 A1IE A1F B0 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FUNCTION Seconds Minutes Hours Day Date Month/ Century Year Alarm 1 Seconds Alarm 1 Minutes Alarm 1 Hours Alarm 1 Day Alarm 1 Date Alarm 2 Minutes Alarm 2 Hours Alarm 2 Day Alarm 2 Date Control Control/ Status SRAM RANGE 00-59 00-59 1-12 + AM/PM 00-23 1-7 00-31 01-12 + Century 00-99 00-59 00-59 1-12 + AM/PM 00-23 1-7 1-31 00-59 1-12 + AM/PM 00-23 1-7 1-31 -- -- 00-FFH Seconds Minutes Hours Day
CLKSEL1 CLKSEL0 0 B6 0 B5
month register) is toggled when the years register overflows from 99 to 00. The day-of-week register increments at midnight. Values that correspond to the day of week are userdefined but must be sequential (i.e., if 1 equals Sunday, then 2 equals Monday, and so on). Illogical time and date entries result in undefined operation. When reading or writing the time and date registers, secondary (user) buffers are used to prevent errors when the internal registers update. When reading the time and date registers, the user buffers are synchronized to the internal registers on any START or STOP
and when the register pointer rolls over to zero. The time information is read from these secondary registers, while the clock continues to run. This eliminates the need to reread the registers in case the main registers update during a read. The countdown chain is reset whenever the seconds register is written. Write transfers occur on the acknowledge from the DS1375. Once the countdown chain is reset, to avoid rollover issues the remaining time and date registers must be written within 1 second. The 1Hz square-wave output, if enabled, transitions high 500ms after the seconds data transfer, provided the clock input is already being driven.
_____________________________________________________________________
7
I2C Digital Input RTC with Alarm DS1375
Alarms
The DS1375 contains two time-of-day/date alarms. Alarm 1 can be set by writing to registers 07h-0Ah. Alarm 2 can be set by writing to registers 0Bh-0Dh. The alarms can be programmed (by the alarm enable and INTCN bits of the control register) to activate the SQW/INT output on an alarm match condition. Bit 7 of the time-of-day/date alarm registers are mask bits (Table 2). When all the mask bits for each alarm are logic 0, an alarm only occurs when the values in the timekeeping registers match the corresponding values stored in the time-of-day/date alarm registers. The alarms can also be programmed to repeat every second, minute, hour, day, or date. Table 2 shows the possible settings. Configurations not listed in the table result in illogical operation. The DY/DT bits (bit 6 of the alarm day/date registers) control whether the alarm value stored in bits 0-5 of that register reflects the day of the week or the date of the month. If DY/DT is written to logic 0, the alarm is the result of a match with date of the month. If DY/DT is written to logic 1, the alarm is the result of a match with day of the week. When the RTC register values match alarm register settings, the corresponding alarm flag A1F or A2F bit is set to logic 1. If the corresponding alarm interrupt enable A1IE or A2IE is also set to logic 1, and the INTCN bit is set to logic 1, the alarm condition activates the SQW/INT signal. The match is tested on the onceper-second update of the time and date registers.
Special Purpose Registers
The DS1375 has two additional registers (control and status) that control the RTC, alarms, and square-wave output.
Table 2. Alarm Mask Bits
DY/DT ALARM 1 REGISTER MASK BITS (BIT 7) A1M X X X 1 1 1 A1M 1 1 1 A1M 1 1 0 A1M 1 0 0 Alarm once per second Alarm when seconds match Alarm when minutes and seconds match Alarm when hours, minutes, and seconds match Alarm when date, hours, minutes, and seconds match Alarm when day, hours, minutes, and seconds match X X X 0 1 ALARM RATE DY/DT ALARM 2 REGISTER MASK BITS (BIT 7) A2M 1 1 1 0 0 A2M 1 1 0 0 0 A2M 1 0 0 0 0 Alarm once per minute (00 seconds of every min) Alarm when minutes match Alarm when hours and minutes match Alarm when date, hours, and minutes match Alarm when day, hours, and minutes match ALARM RATE
X
1
0
0
0
0
0
0
0
0
1
0
0
0
0
8
_____________________________________________________________________
I2C Digital Input RTC with Alarm
Control Register (0Eh)
Bit 7 ECLK Bit 6 CLKSEL1 Bit 5 CLKSEL0 Bit 4 RS2 Bit 3 RS1 Bit 2 INTCN Bit 1 A2IE Bit 0 A1IE
DS1375
Control Register (0Eh)
Bit 7/Enable Clock (ECLK). When ECLK is set to logic 1, the CLK input pin is enabled to clock the internal divider chain and advance the timekeeping registers. When ECLK is set to logic 0, the divider chain is held in reset, and the time is not allowed to advance. To synchronize the DS1375 time to a reference, write the ECLK bit to 0, write the time value, then write ECLK back to 1. Doing so synchronizes the time value to within one period of the CLK pin from the point in the interface protocol where the ECLK bit is written. ECLK is set to logic 1 when power is first applied. Bits 6, 5/Clock Select Bits 1, 0 (CLKSEL1, CLKSEL0). These bits determine how the CLK input pin is divided down to get the 1Hz reference clock for the timekeeping registers (Table 3). The CLKSEL0-1 bits are cleared to logic 0 when power is first applied. Bits 4, 3/Rate Select (RS2 and RS1). These bits control the frequency of the square-wave output when the square wave has been enabled and the CLKSEL0 and CLKSEL1 bits are set to 0. Table 3 shows the squarewave frequencies that can be selected with the RS bits. These bits are set to logic 1 (8.192kHz) when power is first applied. If either CLKSEL0 or CLKSEL1 are logic 1, the 1Hz signal is output.
Bit 2/Interrupt Control (INTCN). This bit controls the SQW/INT signal. When the INTCN bit is set to logic 0, a square wave is output on the SQW/INT pin. When the INTCN bit is set to logic 1, a match between the timekeeping registers and either of the alarm registers activates the SQW/INT (if the alarm is also enabled). The corresponding alarm flag is always set, regardless of the state of the INTCN bit. The INTCN bit is set to logic 0 when power is first applied. Bit 1/Alarm 2 Interrupt Enable (A2IE). When set to logic 1, this bit permits the alarm 2 flag (A2F) bit in the status register to assert SQW/INT (when INTCN = 1). When the A2IE bit is set to logic 0 or INTCN is set to logic 0, the A2F bit does not initiate an interrupt signal. The A2IE bit is disabled (logic 0) when power is first applied. Bit 0/Alarm 1 Interrupt Enable (A1IE). When set to logic 1, this bit permits the alarm 1 flag (A1F) bit in the status register to assert SQW/INT (when INTCN = 1). When the A1IE bit is set to logic 0 or INTCN is set to logic 0, the A1F bit does not initiate the SQW/INT signal. The A1IE bit is disabled (logic 0) when power is first applied.
Table 3. CLK Input Frequency, Square-Wave Output Frequency
INTCN 1 0 0 0 0 0 0 0 CLKSEL1 X 0 0 0 0 0 1 1 CLKSEL0 X 0 0 0 0 1 0 1 INPUT FREQUENCY As selected 32,768Hz 32,768Hz 32,768Hz 32,768Hz 8192Hz 60Hz 50Hz RS2 X 0 0 1 1 X X X RS1 X 0 1 0 1 X X X SQUARE-WAVE OUTPUT FREQUENCY N/A (Interrupt) 1Hz 1.024kHz 4.096kHz 8.192kHz 1Hz 1Hz 1Hz
_____________________________________________________________________
9
I2C Digital Input RTC with Alarm DS1375
Status Register (0Fh)
Bit 7 0 Bit 6 0 Bit 5 0 Bit 4 0 Bit 3 0 Bit 2 0 Bit 1 A2F Bit 0 A1F
Status Register (0Fh)
Bit 1/Alarm 2 Flag (A2F). A logic 1 in the alarm 2 flag bit indicates that the time matched the alarm 2 registers. If the A2IE bit is logic 1 and the INTCN bit is set to logic 1, the SQW/INT pin is also asserted. A2F is cleared when written to logic 0. This bit can only be written to logic 0. Attempting to write to logic 1 leaves the value unchanged. Bit 0/Alarm 1 Flag (A1F). A logic 1 in the alarm 1 flag bit indicates that the time matched the alarm 1 registers. If the A1IE bit is logic 1 and the INTCN bit is set to logic 1, the SQW/INT pin is also asserted. A1F is cleared when written to logic 0. This bit can only be written to logic 0. Attempting to write to logic 1 leaves the value unchanged.
through the open-drain I/O lines SDA and SCL. Within the bus specifications a standard mode (100kHz max clock rate) and a fast mode (400kHz max clock rate) are defined. The DS1375 works in both modes. The following bus protocol has been defined (Figure 3): * Data transfer can be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is high. Changes in the data line while the clock line is high can be interpreted as control signals. Accordingly, the following bus conditions have been defined: Bus not busy: Both data and clock lines remain high. Start data transfer: A change in the data line's state from high to low, while the clock line is high, defines a START condition. Stop data transfer: A change in the data line's state from low to high, while the clock line is high, defines a STOP condition. Data valid: The data line's state represents valid data when, after a START condition, the data line is stable for the duration of the high period of the clock signal. The data on the line must be changed *
I2C Serial Data Bus
The DS1375 supports a bidirectional I2C bus and data transmission protocol. A device that sends data onto the bus is defined as a transmitter and a device receiving data as a receiver. The device that controls the message is called a master. The devices that are controlled by the master are slaves. A master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions must control the bus. The DS1375 operates as a slave on the I2C bus. Connections to the bus are made
MSB FIRST SDA
MSB
LSB
MSB
LSB
SLAVE ADDRESS
R/W
ACK
DATA
ACK
DATA
ACK/ NACK
SCL
1-7
8
9
1-7
8
9
1-7
8
9
IDLE
START CONDITION
REPEATED IF MORE BYTES ARE TRANSFERRED
STOP CONDITION REPEATED START
Figure 3. I2C Data Transfer Overview
10 ____________________________________________________________________
I2C Digital Input RTC with Alarm
during the low period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data bytes transferred between the START and the STOP conditions is not limited, and is determined by the master device. The information is transferred byte-wise and each receiver acknowledges with a ninth bit. Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the reception of each byte. The master device must generate an extra clock pulse that is associated with this acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable low during the high period of the acknowledge-related clock pulse. Setup and hold times must be taken into account. A master must signal an end of data to the slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data line high to enable the master to generate the STOP condition. Figures 4 and 5 detail how data transfer is accomplished on the I2C bus. Depending upon the state of the R/W bit, two types of data transfer are possible: Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the master is the slave address. Next follows a number of data bytes. The slave returns an acknowledge bit after each received byte. Data transfer from a slave transmitter to a master receiver. The master transmits the first byte (the slave address). The slave then returns an acknowledge bit. Next follows a number of data bytes transmitted by the slave to the master. The master returns an acknowledge bit after all received bytes, other than the last byte. At the end of the last received byte, a not acknowledge is returned. The master device generates all the serial clock pulses and the START and STOP conditions. A transfer is ended with a STOP condition or with a repeated START condition. Since a repeated START condition is also the beginning of the next serial transfer, the bus is not released. The DS1375 can operate in the following two modes: Slave Receiver Mode (Write Mode): Serial data and clock are received through SDA and SCL. After each byte is received, an acknowledge bit is transmitted. START and STOP conditions are recognized as the beginning and end of a serial transfer. Address recognition is performed by hardware after reception of the slave address and direction bit. The slave address byte is the first byte received after the master generates the START condition. The slave address byte contains the 7-bit DS1375 address, which is 1101000, followed by the direction bit (R/W), which is 0 for a write. After receiving and decoding the slave address byte, the DS1375 outputs an acknowledge on SDA. After the DS1375 acknowledges the slave address + write bit, the master transmits a word address to the DS1375. This sets the register pointer on the DS1375, with the DS1375 acknowledging the transfer. The master can then transmit zero or more bytes of data, with the DS1375 acknowledging each byte received. The register pointer increments after each data byte is transferred. The master generates a STOP condition to terminate the data write. Slave Transmitter Mode (Read Mode): The first byte is received and handled as in the slave receiver mode. However, in this mode, the direction bit indicates that the transfer direction is reversed. The DS1375 transmits serial data on SDA while the serial clock is input on SCL. START and STOP conditions are recognized as the beginning and end of a serial transfer. Address recognition is performed by hardware after reception of the slave address and direction bit. The slave address byte is the first byte received after the master generates the START condition. The slave address byte contains the 7-bit DS1375 address, which is 1101000, followed by the direction bit (R/W), which is 1 for a read. After receiving and decoding the slave address byte, the DS1375 outputs an acknowledge on SDA. The DS1375 then begins to transmit data starting with the register address pointed to by the register pointer. If the register pointer is not written to before the initiation of a read mode, the first address that is read is the last one stored in the register pointer. The DS1375 must receive a not acknowledge to end a read.
DS1375
____________________________________________________________________
11
I2C Digital Input RTC with Alarm DS1375
S 1101000 0 A XXXXXXXX A XXXXXXXX A XXXXXXXX A ...
XXXXXXXX
A
P
S - START SLAVE TO MASTER A - ACKNOWLEDGE (ACK) P - STOP R/W - READ/WRITE OR DIRECTION BIT ADDRESS
MASTER TO SLAVE DATA TRANSFERRED (X + 1 BYTES + ACKNOWLEDGE)
Figure 4. Data Write--Slave Receiver Mode
S 1101000
1 A
XXXXXXXX A
XXXXXXXX SLAVE TO MASTER A
XXXXXXXX A ...
XXXXXXXX A P
S - START MASTER TO SLAVE A - ACKNOWLEDGE (ACK) P - STOP A - NOT ACKNOWLEDGE (NACK) R/W - READ/WRITE OR DIRECTION BIT ADDRESS
DATA TRANSFERRED (X + 1 BYTES + ACKNOWLEDGE) NOTE: LAST DATA BYTE IS FOLLOWED BY A NACK.
Figure 5. Data Read--Slave Transmitter Mode
S 1101000 0 A
XXXXXXXX
A Sr 1101000 1 A
XXXXXXXX A
XXXXXXXX A
XXXXXXXX A

...
XXXXXXXX
A
P
S - START MASTER TO SLAVE Sr - REPEATED START A - ACKNOWLEDGE (ACK) P - STOP A - NOT ACKNOWLEDGE (NACK) R/W - READ/WRITE OR DIRECTION BIT ADDRESS
SLAVE TO MASTER DATA TRANSFERRED (X + 1 BYTES + ACKNOWLEDGE) NOTE: LAST DATA BYTE IS FOLLOWED BY A NACK.
Figure 6. Data Write/Read (Write Pointer, Then Read)--Slave Receive and Transmit
Chip Information
TRANSISTOR COUNT: 11,797 PROCESS: CMOS SUBSTRATE CONNECTED TO GROUND
Package Information
For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. PACKAGE TYPE 6 TDFN-EP PACKAGE CODE T633+2 DOCUMENT NO. 21-0137
Thermal Information
Theta-JA: 41C/W Theta-JC: 2C/W
12
____________________________________________________________________
I2C Digital Input RTC with Alarm
Revision History
REVISION NUMBER 0 REVISION DATE 4/03 Initial release. Changed the package reference from TQFN to TDFN in the Ordering Information and Pin Configuration. Added link to the package drawing in the Package Information section. Globally replaced "2-wire" with "I2C". Updated the Ordering Information to include the lead-free package; updated the Pin Configuration to show the lead-free exposed pad package. 2 9/08 In the Pin Description, indicated that SCL, SDA, and SQWINT can be pulled up to 5.5V; also added the exposed pad information. Added time and date POR information to the Detailed Description. Replaced the I2C write and read figures. Added the Package Information section table. DESCRIPTION PAGES CHANGED -- 1 11 All 1 6 6 12 12
DS1375
1
1/04
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 13
(c) 2008 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc.
is a registered trademark of Dallas Semiconductor Corporation.


▲Up To Search▲   

 
Price & Availability of DS1375T

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X